Double heads keg washing machine

›

‹

›

Double heads keg washing machine

Get Quote Now

Double heads keg washing machine


Specification

table-board size1200mm×450mm
table-board height700mm
exterior dimension1200mm×1400mm×1900mm
cylinder max stroke300mm
net weight260Kg
power18KW
Heating (electrical heating) 220V three-phase
capacity20~40kegs/hour
cleaning modekeg topside down
applicable kegdiameter φ250~φ500,   height 360mm~600mm


Technical parameter

air source pressure0.6~0.7Mpa
CO2 source pressure0.3~0.4Mpa
cylinder valve pressure0.5~0.6Mpa
CO2 valve pressure0.2~0.3Mpa
Air-blow valve pressure0.2Mpa
sterile water pressure0.4Mpa
power voltageThree-phase   220V 60Hz


Main Structures and Features

This machine mainly contains the frame, electric system, air system and other pipeline system. The features are as below:

1. All parameters (time values) can be adjusted without stopping the machine.

2. Maximum straight-line design on main cleaning pipelines makes sure the powerful and thorough scouring.

3. Twin-acting pneumatic valve with reliable quality and anti-high temperature characteristic.

4. Adoption of world top products as main accessories makes sure premium quality.

5. The sterile water and the lye water can be recyclable.

 

 Working Procedures

Load the keg → start (cylinder pressing tightly) → air blowing (draining residue) → scoured by clean water → air blowing (draining water) → scoured by lye water → extracting tube scoured by lye water → air blowing and recycle → scoured by clean water → extracting tube scoured by clean water→ air blowing (draining water) → scoured by clean water → air blowing → scoured by sterile water → air blowing → prepare CO2 pressure → reset the cylinder → unload the keg

 

 Usual Malfunction and Removing Method

MalfunctionPossible reasonMoving method
Leakage of cleaning headloose cylindercheck the cylinder pressure
incorrect orientationorient the keg correctly
loose gasketAdjust gasket
Power disconnection of PLCincorrect voltage valuecheck the power
high ampere value(≥3A)check the circuit
Extinguishing of indicatorIndicator damagechange the indicator
Remaining liquid in keg after cleaning processinsufficient air-blowing timeadjust air-pumping time
damaged extracting tubechange extracting tube
Virus standard unconformityexpired disinfectantchange disinfectant 


Get Quote Now 

Send